Repairs
2016-03-02 / DIS 840_58300000176874_ara_en_c
Copyright by BSH Hausgeräte GmbH
Page 69 of 157
3. Press together the hose clamp (1) and push to the side (2).
4. Pull the hose from the support of the inlet valve (1).
5. Remove the inlet valve together with the retainer plate.
6.11.2
Installing the inlet valve
The inlet valve is delivered complete with retaining flap.
1. Install the inlet valve with the retainer plate in reverse order.
2. Check the tightness.