Test
2016-03-02 / DIS 840_58300000176874_ara_en_c
Copyright by BSH Hausgeräte GmbH
Page 43 of 157
5.11
Checking the door sensor
For measurements, see the circuit diagrams.
Prerequisite:
•
Appliance is disconnected from the power supply.
•
Cabinet panel has been removed (optional).
•
Outer door has been removed.
•
Control panel has been removed. (Page 64)
•
Right-hand side panel has been removed. (Page 115)
Risk of electric shock due to live parts when performing tests
on an energised system!
► For tests on an energised system, use a residual current circuit
breaker.
► Do not touch the housing, frame, components and cables.
Plug contacts may be damaged!
►
Check the plug contact. (Page 40)
1. Remove the screws (1). Remove the door sensor and keep (2).
2. Release the electrical connector to the door sensor (1) and unplug it (2).
3. Measure the resistance at the door sensor.