Repairs
2016-03-02 / DIS 840_58300000176874_ara_en_c
Copyright by BSH Hausgeräte GmbH
Page 122 of 157
6.37.2
Connect the UDA to the power module
Improper handling!
Risk of short circuit. Destruction of the power module.
► Connect the UDA plug only to the connection described.
► Connect the UDA only with the plugged in coding frame to the upper side of
the module.
The Y cable must
not
be used for this connection.
If the iService connection x9 is occupied by another consumer,
unplug (1).
1. Connect the UDA connection cable in the marked iService /D-2 bus connection
x9 to the upper connector strip (2).
2. Establish a connection to the UDA.
.
If the UDA is operated on another connection, this can lead to
damage to the power module and to the UDA.
Connect the UDA connection only with the plugged in coding
frame to the upper side of the module. Otherwise, there is a
risk of short circuit!