Test
2016-03-02 / DIS 840_58300000176874_ara_en_c
Copyright by BSH Hausgeräte GmbH
Page 31 of 157
5.3
Checking the inlet valve
5.3.1
Checking the function and tightness of the inlet valve
1. Checking for correct installation (correct connection, hoses not kinked)
2. Visually inspect the connection for water droplets.
3. Measure the flow rate (2.5 l/min)
4.
0
If a flow rate of 2.5 l/min is not reached
1) check the filter in the inlet valve for dirt or blockage.
2) Tap is furred up.
5.
0
If the flow rate of 2.5 l/min is exceeded
► the flow limiter is defective --> replace the valve.
6.
0
If you cannot find any reason for the fault
► test the component electronically.
5.3.2
Checking the inlet valve electrically
For measurements, see the circuit diagrams.
Prerequisite:
•
Appliance is disconnected from the power supply.
•
The water tap is closed.
•
Appliance is freely accessible.
•
The rear of the appliance is accessible.
Plug contacts may be damaged
►
Check the plug contact. (Page 40)
1. Unscrew the inlet hose (1). Release catch element (2) and open out the
retainer plate (3).