Test
2016-03-02 / DIS 840_58300000176874_ara_en_c
Copyright by BSH Hausgeräte GmbH
Page 32 of 157
2. Release the electrical connector to the inlet valve (1) and unplug it (2).
3. Measure the resistance of the inlet valve coil.
4.
0
If the resistance
does not
agree with the value given in the circuit diagram
►
replace the defective inlet valve. (Page 68)
5.
0
If the resistance does agree with the value given in the circuit diagram
► check the line resistance R at the plug-in connections.
6.
0
If the line or plug-in connection is interrupted (R > 0)
► replace the defective cable harness.
7.
0
If the line is intact (R = 0)
►
replace the defective power module. (Page 91)