Test
2016-03-02 / DIS 840_58300000176874_ara_en_c
Copyright by BSH Hausgeräte GmbH
Page 39 of 157
5.8
Checking the spray arm system
Prerequisite:
•
The appliance is connected to the power supply.
•
The viewing door has been mounted.
5.8.1
Checking the spray arm system for malfunctions
1. Check the fault memory for water switch faults.
2. Start the customer service test programme and wait until the water switch is
actuated.
3. Clean or replace the spray arms.
.
If the spray arms are obstructed by tableware, explain to the
customer how to avoid this. (For correct loading, see IM)
5.8.2
Checking the installation
You should always make sure that the spray arm is installed horizontally.
1. Make sure that the position of the two suspension hooks is horizontal relative to
the bottom of the upper basket.
2. Make sure that the upper basket is mounted horizontally. This could be a
reason for the spray arms being at an angle.