HCS03.1E-W0xxx-A-05-xxxN) with CSB02 or CSH02 control section
●
IndraDrive M (HMS01, HMS02) with CSB02 or CSH02 control section
●
IndraDrive M (HMD01) with CDB02 control section
All IndraDrive C and IndraDrive M power sections produced since
2007 can use the Cxx02 control sections. See power section type
plate: "FD" must say at least "07W01".
●
IndraDrive ML (HMU05.1) with CSB02.5 or CSH02.5 control section
For pin assignments and technical data of the optional safety
technology module "L3", please refer to the Appendix: "
optional safety technology L3 or L4
".
Optional safety technology module "L4"
Using the "Safe Torque Off" and "Safe Brake Control" function requires the
optional safety technology module "L4". The optional module can be ordered
for the following controllers:
●
IndraDrive Cs Basic (HCS01.1E-W00**-A0*-B)
●
IndraDrive Cs Economy (HCS01.1E-W00**-A0*-E)
●
IndraDrive Cs Advanced (HCS01.1E-W00**-A0*-A)
For pin assignments and technical data of the optional safety
technology module "L4", please refer to the Appendix: "
optional safety technology L3 or L4
".
DOK-INDRV*-SI3-**VRS**-AP06-EN-P
Rexroth IndraDrive Integrated Safety Technology "Safe Torque Off" (as of MPx-16)
Bosch Rexroth AG
85/149
Commissioning the safety technology
LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01