7.1.2
STO and SBC functions ("L4" only) when selected by means of active
safety units
Dual-channel wiring
Plus-plus-switching safety unit
When the safety function is selected by means of a plus-plus-switching safety
unit, the following errors must be detected by the OSSD outputs:
●
Short circuit of the selection signals with 24 V
●
Short circuit between the two selection signals
Fig. 7-3:
STO function and SBC function (only IndraDrive Cs with "L4") with ac‐
tive safety unit (plus-plus-switching outputs)
Plus-minus-switching safety unit
When the safety function is selected by means of a plus-minus-switching
safety unit, the following errors must be detected by the OSSD outputs:
●
Short circuit of the plus-switching selection signal against 24 V
●
Short circuit of the minus-switching selection signal against 0 V