KCU, KSM 3
Safety zone beginner
KSM 1, KSM 4
Safety zone node
KSM 2
KSM without optional safety technology ⇒ not a safety
zone node
RBS0023
Connector for safety zone node at connection point
X141 (only required for KSM/KMS with optional safety
technology)
RKB0033
Cable for transmitting the safety-related signals
S 1, S 2
Signals of the individual safety zones
SI Zone 1, SI Zone 2 Safety zones
X49, X141
Connection points of safety technology
Fig. 12-10:
Safety zones
Safety zone beginner
A
Monitoring electronics in KCU
H49
Diagnostic display for safety technology signals
Fig. 12-11:
Safety zone beginner KCU
Two options for signal input:
Bosch Rexroth AG
DOK-INDRV*-SI3-**VRS**-AP06-EN-P
Rexroth IndraDrive Integrated Safety Technology "Safe Torque Off" (as of MPx-16)
140/149
Project planning
LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01