Hall unit digital
Digital Hall units for MCL from Rexroth create three rectangular signals,
which are phase-delayed by 120°. The signals of an open-collector-switch
are provided on the lines according to Fig.
. The voltage supply is 3 ... 24
V. The voltage supply must ensure a current consumption of the Hall unit of
minimum 40 mA.
Fig. 7-2:
Signal curve of a digital Hall unit
The signal height of the digital Hall unit is depending on the volt‐
age supply of open-collector-switch. Bosch Rexroth contoller use
a voltage supply of 5 V.
DOK-MOTOR*-MCL********-PR05-EN-P
Bosch Rexroth AG
79/193
Rexroth IndraDyn L Ironless Linear Motors MCL