9.21
Deactivation upon EMERGENCY STOPand in the event of a
malfunction
9.21.1
General
The deactivation of an axis, equipped with an IndraDyn L motor, can be initi‐
ated by
●
EMERGENCY STOP,
●
Drive fault (e.g. response of the encoder monitoring function) or
●
Mains failure
For the options of deactivation an IndraDyn L motor in the event of a malfunc‐
tion, distinction must be made between
●
Deactivation by the drive,
●
Deactivation by a master control and
●
Deactivation by a mechanical braking device.
9.21.2
Deactivation by the drive
As long as there is no fault or malfunction in the drive system, shutdown by
the drive is possible. The shutdown possibilities depend on the occurred drive
error and on the selected error response of the drive. Certain faults (interface
faults or fatal faults) lead to a force disconnection of the drive.
Death, serious injuries or damage to equip‐
ment may result from an uncontrolled coast‐
ing of a switched-off linear drive!
WARNING
⇒ Construction and design according to the safety standards
⇒ Protection of people by suitable barriers and enclosures
⇒ Using external mechanical braking facilities
⇒ Use suitable energy-absorbing end position shock absorber
The parameter values of the drive response to interface faults and non-fatal
faults can be selected. The drive switches off at the end of each fault re‐
sponse.
The following fault responses can be selected:
0 – Setting velocity command value to zero
1 - Setting force command value to zero
2 - Setting velocity command value to zero with command value ramp and fil‐
ter
3 - Retraction
Please refer to the corresponding firmware function description
for additional information about the reaction to faults and the rela‐
ted parameter value assignments.
Bosch Rexroth AG
DOK-MOTOR*-MCL********-PR05-EN-P
124/193
Rexroth IndraDyn L Ironless Linear Motors MCL
Application and construction instructions
Summary of Contents for DOK-MOTOR-MCL Series
Page 14: ...Bosch Rexroth AG DOK MOTOR MCL PR05 EN P 12 193 Rexroth IndraDyn L Ironless Linear Motors MCL ...
Page 48: ...Bosch Rexroth AG DOK MOTOR MCL PR05 EN P 46 193 Rexroth IndraDyn L Ironless Linear Motors MCL ...
Page 64: ...Bosch Rexroth AG DOK MOTOR MCL PR05 EN P 62 193 Rexroth IndraDyn L Ironless Linear Motors MCL ...
Page 78: ...Bosch Rexroth AG DOK MOTOR MCL PR05 EN P 76 193 Rexroth IndraDyn L Ironless Linear Motors MCL ...
Page 84: ...Bosch Rexroth AG DOK MOTOR MCL PR05 EN P 82 193 Rexroth IndraDyn L Ironless Linear Motors MCL ...
Page 98: ...Bosch Rexroth AG DOK MOTOR MCL PR05 EN P 96 193 Rexroth IndraDyn L Ironless Linear Motors MCL ...