Control Panel
Schedules | en
221
Bosch Security Systems, Inc.
Program Entry Guide
2017.03 | 09 | F.01U.303.998
The entry in the Parameter 1: Output # prompt defines the specific output this function
activates. The function can activate one output.
11.5.12
Turn Output Off
This function emulates the Change Output State keypad shortcut to turn outputs off.
The entry in the Parameter 1: Output # prompt defines the specific output this function
deactivates. The function can deactivate one output.
11.5.13
Toggle Output
This function is not available as a keypad shortcut function. The entry in the Parameter 1:
Output # prompt defines the specific output this function toggles. If the output is on, it is
turned off. If the output is off, it is turned on. The function has effect on one output.
11.5.14
One-Shot Output
This function is not available as a keypad shortcut function and is only available as a custom
function. The function activates the output selected in Parameter 1 for the number of seconds
selected in Parameter 2.
11.5.15
Reset All Outputs
This function is not available as a keypad shortcut function. This function turns off all outputs
that are turned on by a sked or custom function. This is a panel-wide function. No other
parameters require input for this option.
11.5.16
Delay
Use this function to create a configurable delay (0 to 90 seconds) between, or before
functions. Parameter 1 configures the delay.
11.5.17
Cycle Door
This function emulates the Cycle Door keypad shortcut function and is only available in a
Custom Function. This function momentarily unlocks the door(s) programmed in Parameter 1:
Door #.
11.5.18
Unlock Door
This function emulates the Unlock Door keypad shortcut function. This function unlocks the
door(s) programmed in Parameter 1: Door #.
11.5.19
Lock Door
This function emulates the Lock Door keypad shortcut function. This function returns the
door(s) programmed in Parameter 1: Door # to their normal locked state.
11.5.20
Secure Door
This function emulates the Lock Door keypad shortcut function. This function returns the
door(s) programmed in Parameter 1: Door # to their normal locked state.
11.5.21
Access Ctrl Level
This function is not available as a keypad shortcut function and determines whether a user's
token or card authority level for access is enabled or disabled.
When Parameter 1: Access Level is set to On, the authority levels programmed in Parameter 2:
Level are granted access.
When Parameter 1: Access Level is set to Off, the authority levels programmed in Parameter 2:
Level are denied access.