Opening/Closing Windows Table
Use this table to determine the proper entries for your application.
Day of week
The column
below briefly
describes the
ways to activate
an Opening/
Closing window.
Use the
guidelines shown
in the other
columns to
choose the
appropriate
entries.
Except on
holiday
Holiday index
Areas
Program at least
one day as YES
Days(s) of the
week
NO
None
Program at least
on area as YES
Program at least
one day as YES
Day(s) of the
week, but NOT
on holidays
YES
Select at least
one Index
Program at least
on area as YES
Program at least
one day as YES
Day(s) of the
week, PLUS
holidays
NO
Select at least
one Index
Program at least
on area as YES
All days must be
programmed NO
Only on holidays
NO
Select at least
one Index
Program at least
on area as YES
11.1.3
Sunday through Saturday
Default (Sunday through Saturday):
No
Selections
: Yes/No
In the seven weekday parameters, select the days of the week that the opening and/or closing
windows are active.
To prevent the windows from activating on certain days of the year, set Xept Holiday, page 215
to Yes, and enable at least one holiday index. When Xept Holiday, page 215 is set to Yes, the
window executes on the days of the week programmed unless the date is designated as a
holiday by the selected holiday index.
If opening and/or closing windows are only needed on certain days of the year, do not
program the windows to execute on any days of the week. Instead, set Xept Holiday, page 215
to No, and select a holiday index with the days of the year you want the window to be active.
RPS Menu Location
Schedules > Open/Close Windows > Sunday through Saturday
11.1.4
Open Early Begin
Default
: Disable
Selections
: Disable, HH:MM (hours and minutes) 00:00 to 23:59