Control Panel
Panel Wide Parameters | en
81
Bosch Security Systems, Inc.
Program Entry Guide
2017.03 | 09 | F.01U.303.998
3.15.16
Remote Warning
Default
: No
Selections
:
–
Yes. The system uses the alarm bell output to annunciate the arming and disarming of an
area through remote software, or a remote arming device (keyswitch, Inovonics Pendant
Transmitter or RADION keyfob).
–
No. No remote warning occurs to annunciate the arming or disarming of an area through
remote software, or a remote arming device (keyswitch, or RADION keyfob).
This parameter pulses the Alarm Bell, page 133 once (2-sec ON, then OFF) when the assigned
area is remotely armed, and twice (2-sec ON, 2-sec OFF, 2-sec ON, then OFF) when the area is
remotely disarmed. This parameter also applies to keyswitch arming and disarming.
Notice!
Type and source of hazard
To comply with SIA CP-01 False Alarm Reduction, set this parameter to Yes. Refer to SIA
CP-01 Verification for more information.
When upgrading a non- control panel account to a control panel account, RPS forces the
default to No.
RPS Menu Location
Panel Wide Parameters > Miscellaneous > Remote Warning
3.15.17
Crystal Time Adjust
Default
: No
Selections
:
–
Yes - the control panel uses the on-board crystal frequency to regulate its clock time.
–
No - the control panel uses traditional AC frequency to regulate its clock time.
This parameter determines how the control panel regulates its clock time.
RPS Menu Location
Panel Wide Parameters > Miscellaneous > Crystal Time Adjust
3.15.18
Part On Output
Default
: No
Selections
:
–
Yes - the Fail to Close outputs become Part On outputs. This output is activated when all
areas assigned to the same output are armed Part On Instant or Part On Delayed.
–
No - the Fail to Close outputs operate when the closing window expires for the specified
area.
This parameter activates outputs when all areas assigned to the same output are armed as
Part On Instant or Part On Delay.
RPS Menu Location
Panel Wide Parameters > Miscellaneous > Part On Output
Further information
Fail to Close/Part On Armed, page 134
3.15.19
Early Area Armed Output
Default
: No
Selections
:
–
Yes - activates the area wide armed or Part On output at the start of Exit Delay time.
–
No - activates the area wide armed or Part On output at the end of Exit Delay time.