6.3.3
Heat pump terminal measurements
There are two connectors, 7-pin and 3-pin.
6.3.3.1 7-pin connector (heater / NTC’s / pump ground)
The 7-pin connector connects to the heat pump heater, NTC’s
and ground.
6.3.3.2 3-pin connector (3-pole BLDC motor)
The 3-pin connector connects to the 3-pole BLDC motor. The
power control module controls motor speed, starting and
stopping.
6.3.4
Drain pump
There is a single 3-pin connector,
connecting to the 3-pole BLDC
pump motor.
Resistances as follows:
1 – 2:
90
Ω
(@ 72 ºF)
2 – 3:
90
Ω
(@ 72 ºF)
3 – 1:
90
Ω
(@ 72 ºF)
Pump
Motor
7 –
NTC 1
6.3.5
Error code E:25 from loose drain pump cover
6 –
NTC common
5 –
NTC 2
If a dishwasher doesn’t drain properly and / or shows an
E:25
error code, the problem could be the drain pump cover wasn’t
replaced properly (i.e. not completely seated and locked into
position). Loose drain pump covers allow more water flow to the
drain pump, increasing the pump load, drawing more current and
causing an
E:25
error code.
4 –
Line (hot)
3 –
X1 (heater common)
2 –
Neutral
1 –
Ground
5
7
6
4 3 2 1
The
Clean
light can come on, giving the impression the
dishwasher finished it’s cycle when it actually didn’t.
Occasionally
E:23
and
E:24
error codes can occur as well.
1. Drain pump cover
1
702_58300000130262_ara_en_c
Page 44 of 50