5.2.3
Base mounted controls (power modules)
Power modules are located in the base on the right side of
dishwashers, not behind fascia panels. So:
Dishwashers must be pulled out to change controls.
Dishwashers must be pulled out to measure voltages &
resistances (at the control).
5.2.3.1
To access base-mounted controls
Tools needed: T20 Torx, # 2 Phillips and flat blade screwdriver.
1.
Remove toe kick
– section 5.1.4.1.
2.
Disconnect & pull out dishwasher
– section 5.1.4.2.
5.2.3.2
To remove base-mounted controls
Tools needed: Flat blade screwdriver
1. Two plastic base tabs hold the power module in place. To
remove power module, gently pry tabs until they clear
module
(below left)
, move bottom of module (in toward
heat pump) until it clears base
(below right)
and pull
module from base.
2. Pry cover tabs to open cover
(below left)
, then disconnect
wire harnesses from power module
(below right)
.
702_58300000130262_ara_en_c