12/16
Operating Instructions ACU
197
Parameter
Setting
No.
Description
Min.
Max.
Factory setting
791 Time 1 Timer 1, signal delay
0.00 s/m/h 650.00 s/m/h
0.00 s/m/h
792 Time 2 Timer 1, signal duration
0.00 s/m/h 650.00 s/m/h
0.00 s/m/h
794 Time 1 Timer 2, signal delay
0.00 s/m/h 650.00 s/m/h
0.00 s/m/h
795 Time 2 Timer 2, signal duration
0.00 s/m/h 650.00 s/m/h
0.00 s/m/h
Examples of the timer function depending on the selected operation mode and the input signal:
Normal, positive edge
Parameter
Operation Mode Timer 1
790
or
Operation Mode Timer 2
793
= 1
As soon as the positive signal edge is received at the input, time 1 is started. Once the Time 1
(signal delay) has elapsed, the output signal will be switched for Time 2 (signal duration).
In the settings for signal duration (
Time 2 Timer 1
792
= 0 and
Time 2 Timer 2
795
= 0), the
output signal will not be reset.
Retrigger, positive edge
Parameter
Operation Mode Timer 1
790
or
Operation Mode Timer 2
793
= 2
As soon as the positive signal edge is received at the input, time 1 is started. If a positive signal
edge is detected within the signal delay (Time 1), Time 1 will start again (Retrigger). Once the Time
1 (signal delay) has elapsed, the output signal will be switched for Time 2 (signal duration).
In the settings for signal duration (
Time 2 Timer 1
792
= 0 and
Time 2 Timer 2
795
= 0), the
output signal will not be reset.
: Time not run out completely
: Time run out completely
Input
Output
Time 2
Time 1
Factory setting (Time 2 = 0)
Input
Output
Time 2
Time 1
Time 1
Facory setting (Time 2 = 0)