Warning mask, application
The application warning mask signals, via a digital signal, if a pre-configured warning is present. The
application warning mask is configured via
Create Appl. Warning Mask
626
.
As soon as limit switches are reached or contouring error thresholds are exceeded, a warning can be
issued. The warning signal refers to the parameter values set in error/warning behavior. Depending
on the application, any number of warnings can be configured. This enables internal and/or external
control using a common output signal. The display of
Application Warnings
273
is not influenced
via the warning mask.
Create Appl. Warning Mask 626
Function
0 - no change
The configured warning mask is not changed.
2 - Activate all warnings
The warnings reports stated are linked in the warning
mask.
10 - Warning V-belt
Operation Mode 581 signals no-load operation of the
application.
11 - Warning pos. SW limit switch
1)
Warning message indicating that the positive SW limit
switch has been reached (parameter
Pos. SW Limit
Switch
1145
).
12 - Warning neg. SW limit switch
1)
Warning message indicating that the negative SW limit
switch has been reached (parameter
Neg. SW Limit
Switch
1146
).
13 - Warning pos. HW limit switch
1)
Warning message indicating that the positive HW limit
switch has been reached.
14 - Warning neg. HW limit switch
1)
Warning message indicating that the negative HW limit
switch has been reached.
15 - Warning Contouring Error
1)
Warning message, indicating that the contouring error
monitoring range adjusted with parameter
Warning
Threshold
1105
has been left.
16 - Warning Encoder
An encoder with data track can generate a warning.
Selection is not effective in the case of encoders without
data track.
17 - User Warnig 1
The signal set at digital input
User Warnig 1
1363
is
active.
18 - User Warnig 2
The signal set at digital input
User Warnig 2
1364
is
active.
102 - Deactivate all warnings
All warnings are deactivated.
110 - Deactivate warning V-Belt
Warning 10 is deactivated.
111 - Deactivate warning pos. SW limit
switch
Warning 11 is deactivated.
112 - Deactivate warning neg. SW limit
switch
Warning 12 is deactivated.
113 - Deactivate warning pos. HW limit
switch
Warning 13 is deactivated.
114 - Deactivate warning neg. HW limit
switch
Warning 14 is deactivated.
115 -
Deactivate Warning Contouring
Error
Warning 15 is deactivated.
116 - Deactivate Warning Encoder
Warning 16 is deactivated.
117 - Deactivate User Warnig 1
Warning 17 is deactivated.
118 - Deactivate User Warnig 2
Warning 18 is deactivated.
1)
Refer to application manual “Positioning”.