Digital Inputs
Function
180 - Warning Motor Protection
Parameterized
Operation Mode
571
of motor circuit breaker
triggered.
181 - Digital Signal 4, EM-
Module
Signal according to operation mode for the digital output of an
extension module
182 - Digital Signal 5, EM-
Module
Signal according to operation mode for the digital output of an
extension module
215 - Warning mask, application
The defined warning mask of parameter
Create Appl. Warning
Mask
626
signals a critical operating point.
216 - Warning, application
All warnings application are deactivated. Display is effected via
parameter
Application Warnings
273
.
270 to 276
Operation modes 70 to 76 of the digital inputs inverted (LOW
active).
282 - Target Position Reached
Reference orientation
469
of axis positioning was reached or
Target Position / Distance
1202
of a
positioning operation was reached (the
current act. position is within the range set in
parameter
Target Window
1165
for a
minimum period of
Target Window Time
1166
.
2)
284 - STOA inverted
3)
Inverted signal status on digital input S1IND/STOA (first shut-
down path STOA of safety function STO - "Safe Torque Off").
285 - STOB inverted
Inverted signal status on digital input S7IND/STOB (second shut-
down path STOB of safety function STO - "Safe Torque Off").
292 - STOA
Signal status on digital input S1IND/STOA (first shut-down path
STOA of safety function STO - "Safe Torque Off").
293 - STOB
Signal status on digital input S7IND/STOB (second shut-down
path STOB of safety function STO - "Safe Torque Off").
320 - EM-S1IND
4)
Signal at digital input 1 of an extension module EM or remote
operation via communication interface.
321 - EM-S2IND
Signal at digital input 2 of an extension module EM or remote
operation via communication interface.
322 - EM-S3IND
Signal at digital input 3 of an extension module EM or remote
operation via communication interface.
520 - EM-S1IND inverted
Operation mode 320 inverted.
521 - EM-S2IND inverted
Operation mode 321 inverted.
522 - EM-S3IND inverted
Operation mode 322 inverted.
526 - S2IND (Hardware)
5)
Digital input S2IND (X210A.4)
527 - S3IND (Hardware)
Digital input S3IND (X210A.5)
528 - S4IND (Hardware)
Digital input S4IND (X210A.6)
529 - S5IND (Hardware)
Digital input S5IND (X210A.7)
530 - S6IND (Hardware)
Digital input S6IND (X210B.1)
531 - MFI1D (Hardware)
Multifunction input MFI1 (X210B.6) in
Operation Mode
452
= 3
– Digital input.
532 - EM-S1IND (Hardware)
Digital input 1 of an extension module EM.
533 - EM-S2IND (Hardware)
Digital input 2 of an extension module EM.
534 - EM-S3IND (Hardware)
Digital input 3 of an extension module EM.
538 to 546
Operation modes 526 to 534 of the digital inputs inverted (LOW
active).
604 - Warning position
controller
6)
Contouring error supervision message. The range set with
parameter
Warning Threshold
1105
was left.
Summary of Contents for active cube 201