B
Appendix B: Gas Type Conversion
88
Blue Seal Evolution Series Gas Convection Ranges
© Copyright Moffat Ltd. 21 June 2016
Amendment 13
- All Other Markets
(*) Measure Burner operating pressure at manifold test point with two burners operating at 'High Flame'
setting.
NAT, LPG & Butane Only - Operating pressure is ex-factory set and is not to be adjusted, unless when
converting between gasses, if required.
(**) TOWN GAS Only - Adjust burner operating pressure using adjustable gas regulator supplied.
Refer to ‘Gas Conversion and Specifications section of this manual for further details.
Natural Gas
Town Gas (**)
Open Burner
Main Burner
Ø 2.45mm
Ø 4.50mm
Pilot Burner ('PF' Models only)
0.30
0.60
Griddle
Main Burner
Ø 2.10mm
Ø 3.40mm
Pilot Burner
0.35
0.60
Burner Aeration Setting
Fully open
Fully open
Oven
Main Burner
Ø 2.60mm
Ø 5.0mm
Pilot Burner
0.35
0.60
Burner Aeration Setting
Fully Open
Fully Open
Supply Pressure
1.13 - 3-40kPa
0.75 - 1.50kPa
Burner Operating Pressure (*)
0.95kPa (*)
0.63kPa (*)
Gas Regulator Cap Screw
Adjustable Regulator
(Adjust to the Burner
Operating Pressure
specified).
LP Gas (Propane)
LP Gas / Butane
Open Burner
Main Burner
Ø 1.50mm
Ø 1.40mm
Pilot Burner ('PF' Models only)
0.20
Griddle
Main Burner
Ø 1.30mm
Ø 1.20mm
Pilot Burner
0.23
Burner Aeration Setting
Fully open
Oven
Main Burner
Ø 1.60mm
Ø 1.45mm
Pilot Burner
0.23
Burner Aeration Setting
Fully Open
Supply Pressure
2.75 - 4.50kPa
Burner Operating Pressure (*)
2.6kPa (*)
Gas Regulator Cap Screw