B
Appendix B: Gas Type Conversion
82
Blue Seal Evolution Series Gas Convection Ranges
© Copyright Moffat Ltd. 21 June 2016
Amendment 13
Open Burners (From Serial No. 718550).
1.
Remove the pot stands, burner caps and burner bodies and the pot stand supports.
2.
Remove injectors and replace with correct size injectors as shown in ‘Gas Specifications Tables’ at end of this section.
3.
Refit the pot stand supports, pot
stands, burner caps and burner
bodies.
4.
Re-light main burners and check
flame size on simmer (LOW) position.
Adjust low fire adjustment screw on open burner gas control valves to obtain
desired flame size.
NOTE:
The 'Low Fire Screw' should be sealed with coloured paint on completion of low
fire adjustment.
Low Fire Screw
For F Options Only,
Unscrew and remove Main Injectors.
For PF Options Only,
Unscrew and remove Main and Pilot
Injectors.