2
Installation
8
Blue Seal Evolution Series Gas Convection Ranges
© Copyright Moffat Ltd. 21 June 2016
Amendment 13
Installation Requirements
Blue Seal gas Range Convection Ovens are designed to provide years of satisfactory service, and correct installation is essential to
achieve the best performance, efficiency and trouble-free operation.
This appliance must be installed in accordance with National installation codes and in addition, in accordance with relevant National /
Local codes covering gas, electrical and fire safety.
AUSTRALIA / NEW ZEALAND:
- AS/NZS 5601
- Gas Installations.
- AS/NZS 3000
- Wiring Rules.
UNITED KINGDOM:
- Gas Safety (Installation & Use) Regulations 1998.
- BS 6173
- Installation of Catering Appliances.
- BS 5440 1 & 2
- Installation Flueing & Ventilation.
- BS 7671
- Requirements for Electrical Installation.
IRELAND:
- IS 820
- Non - Domestic Gas Installations.
Installations must be carried out by authorised persons only. Failure to install equipment to the relevant codes and
manufacturer’s specifications shown in this section will void the warranty.
Components having adjustments protected (e.g. paint sealed) by the manufacturer are only to be adjusted by an
authorised service agent. They are not to be adjusted by the installation person.
Unpacking
Remove all packaging and transit protection from the appliance including all protective plastic coating from the exterior
stainless steel panels.
Check equipment and parts for damage. Report any damage immediately to the carrier and distributor.
Report any deficiencies to the distributor who supplied the appliance.
Check that the available gas and electrical supply is correct to that shown on the rating plate located on the front right hand
corner of the bottom sill.
Location
1.
Installation must allow for a sufficient flow of fresh air for the combustion air supply.
2.
Installation must include adequate ventilation means, to prevent dangerous build up of combustion products.
3.
Never directly connect a ventilation system to the appliance flue outlet.
4.
Position the appliance in its approximate working position.
5.
All air for burner combustion is supplied from underneath the appliance. The legs must always be fitted and no obstructions
placed on the underside or around the base of the appliance, as obstructions will cause incorrect operation and / or failure of
the appliance.
NOTE: Do not obstruct or block the appliances flue. Never directly connect a ventilation system to the appliance flue
outlet.
Clearances
NOTE:
Only non-combustible materials can be used in close proximity to this appliance.
* Side clearances can be 50mm when the adjacent surface is at least 100mm below cooking surface.
Combustion Air Requirements:
G54
G56
G58
Natural Gas (G20)
37 m
3
/hr 51
m
3
/hr 66
m
3
/hr
LPG (G31)
38 m
3
/hr 53
m
3
/hr 68
m
3
/hr
Town Gas
37 m
3
/hr 51
m
3
/hr 66
m
3
/hr
Combustible Surface
Non Combustible Surface
Left / Right hand side
250mm (*)
0mm
Rear
100mm
0mm