6
Service Procedures
27
Blue Seal Evolution Series Gas Convection Ranges
© Copyright Moffat Ltd. 21 June 2016
Amendment 13
6.2.4 Open Burner Thermocouple
1.
Remove front control panel (refer 6.1.1).
2.
Remove both pot stands front and rear (refer 6.2.1).
3.
Remove burner caps and bowls front and rear (refer
6.2.1).
4.
Remove burner guard (refer 6.2.1).
5.
Undo thermocouple from bottom of burner bracket and
rear of gas control, remove thermocouple and replace.
6.
Re-assemble in reverse order.
Ensure when re-assembling that burner bowls are seated
correctly on locating pins.
NOTE: When screwing thermocouple back into gas
control, once threaded up tighten up another ¼
turn only.Do not over-tighten.
Figure 6.2.4c
Figure 6.2.4d
Thermocouple Bracket
Securing Nut
Thermocouple to Gas
Control Connection
6.2.5 Open Burner Gas Control
1.
Remove control panel (refer 6.1.1).
2.
Undo open burner gas supply line from gas control.
3.
Undo thermocouple from rear of gas control.
4.
Undo Manifold supply connection to gas control.
5.
Remove pilot supply line from gas control (Pilot flame
models only).
6.
Remove gas control.
7.
Replace and re-assemble in reverse order.
8.
Check for gas leaks.
NOTE: When screwing thermocouple back into gas
control, once threaded up tighten up another ¼
turn only. Do not over-tighten.
Figure 6.2.5a
Figure 6.2.5b
Thermocouple to Gas
Control Connection
Open Burner Gas
Supply Line
Gas Control
Supply Connection