62
4.13.1.2 Amplitude
:SOURce:VOLTage[:AMPLitude] <p-p amplitude>
The amplitude command is used to set the peak-to-peak amplitude of the output waveform. Note that the
amplitude and the offset are limited by the relation
Peak Amp |Offset|
≤
5V
Arguments
Type:
Numeric
Units:
V, mV, VPP, mVPP
Range:
10mV to 10V
Rounding:
1mV from 10mV to 999mV. 10mV from 1V to 10V.
Command Type: Setting or Query
Setting
Syntax:
[:SOURce]:VOLTage:AMPLitude<ws><amplitude>[units]
[:SOURce]:VOLTage:AMPLitude<ws>MINimum|MAXimum
Examples:
:VOLT:AMPL 2.5
:VOLT:AMPL 2.5V
:VOLT:AMPL MAX
Query
Syntax:
[:SOURce]:VOLTage:AMPLitude?
[<ws>MINimum|MAXimum]
Examples:
:VOLT:AMPL?
:VOLT:AMPL? MAX
Response:
NR2
Considerations:
1) The MAXimum amplitude is dependent on the offset.
2) The MAX and MIN arguments should not be used in a program message containing an OFFSet
command, since these values are evaluated during parsing, based on the current value of the offset.
4.13.1.3 Offset
:SOURce:VOLTage:OFFSet <offset>
The offset command is used to set the DC offset of the output waveform. Note that the amplitude and the offset are
limited by the relation
Peak Amp |Offset|
≤ 5V
Arguments
Type:
Numeric
Units:
V, mV
Range:
10mV to 4.99V
Rounding:
to 10mV
Command Type: Setting or Query
Setting
Syntax:
[:SOURce]:VOLTage:OFFSet<ws><offset>[units]
[:SOURce]:VOLTage:OFFSet<ws>MINimum|MAXimum
Examples:
:VOLT:OFFS 2.5
:VOLT:OFFS 2.5V
:VOLT:OFFS MAX
Query