34
List of Stored Parameters
Stored Parameters
FREQUENCY
RATE(ARB)
AMPLITUDE
FUNCTION
OFFSET
REPETITION
MODE
N-BURST
START ADRS
WAVELENGTH
TRIG SOURCE
OUTPUT
SWEEP
MODULATION
**
The RECALL and STORE function can be used as a tool to store and locate many arbitrary
waveforms. Because the 4076 and 4079 are designed with one large memory bank (up to
4,000,000 points of storage), users can have the freedom to store as many waveforms of different
lengths as they desired in a dynamic fashion (with the limit of total points not to exceed memory
capacity). Then, by using STORE and RECALL functions to save the starting address and
lengths of each created arbitrary waveforms, users can quickly locate (in the memory) and
output each of the different waves. These functions can behave like reference points, so users
can actually save up to 49 different waveform reference points in the memory.
See example illustration below to see how it works:
Stored Buffer number
Data points of different waveforms
(Start a length)
1
A pts.
2
B pts.
3
C pts.
4
D pts.
From the above illustration, all the points of Waveform 1 can be stored and recalled using buffer #1.
Likewise, Waveform 2 can be stored/recalled by buffer #2. Waveform 3 by buffer #3. Waveform 4 by
buffer #4.
1
4,000,000
Waveform 1
Waveform 4
Waveform 2
Waveform 3
A pts.
B pts.
C pts.
D pts.
A pts. + B pts. + C pts. + D pts.
≤
4,000,000 pts.
Point
Point