MERCURY PLUS
1-237
upgrade the
firmware to version
3.0.0 or more
recent.
609
The scale or
remote control
board has given an
incorrect response
to a command.
Make sure that the
version of the line
firmware and board
are compatible.
610
The scale or
remote control
board has given a
response to a
command ruined
by an interference.
heck the wiring and
connector and
cable filtering.
Make sure that
there is no
interference in the
surrounding
environment.
Exclude the
presence of
electromagnetic
discharges.
Replace the board
if necessary.
611
Serious error inside
the software.
Contact the
software office.
612
Zero not stable
The attempt to
reset the scale has
not been
successful since
the stable weight
condition has not
been reached
within a preset
time.
Make sure that
there were no
oscillatory
phenomena on the
scale plate during
the resetting
procedure (air, lift
truck driving past,
etc.). Check the
scale calibration.
613-619
Serious errors
inside the software.
Contact the
software office.
620
Scale loaded or not
calibrated
The attempt to
reset the scale has
not been
successful since
the scale contains
Unload the scale.
Check the scale
calibration.
Summary of Contents for Cigiemme MERCURY PLUS
Page 1: ...MERCURY PLUS Instruction manual Code 81320114 EDITION 02 05 2016 January 2007 ...
Page 2: ......
Page 12: ...MERCURY PLUS 1 12 ...
Page 62: ...MERCURY PLUS 1 62 ...
Page 94: ...MERCURY PLUS 1 94 5 9 List of menus Figure 5 2 1 3 menu list citi6117 en jpg ...
Page 95: ...MERCURY PLUS 1 95 Figure 5 3 2 3 menu list citi6118 en jpg ...
Page 96: ...MERCURY PLUS 1 96 Figure 5 4 3 3 menu list citi6119 en jpg ...
Page 194: ...MERCURY PLUS 1 194 ...
Page 196: ...MERCURY PLUS 1 196 Figure 6 1 Permit combinations citi6134 jpg ...
Page 234: ...MERCURY PLUS 1 234 ...
Page 250: ...MERCURY PLUS 1 250 ...
Page 259: ......