MERCURY PLUS
1-31
1.8.2 Table of electrical values
Power supply:
240 +10%-15% Vac 50/60 Hz
Load cells that can be connected: up to 4 350 Ohm analog cells on
the 9-pin connector
Analog load cell power:
10 Vdc
Resolution:
up to 10000 divisions
Maximum input signal:
23 mV
Sensitivity:
0.75 uV/division (version with
analog cells)
Full scale stability:
< 5 ppm/°C
Zero stability:
< 5 ppm/°C
Compensated temperature range: 0 + 40 °C
Operating range:
0 + 50 °C
Humidity:
85 % @ 40°C
Table 1.1 - Electrical values
Version
Panel
On top
printing
unit
Underneath
printing
unit
Optional
CGM
Totalizer
3 belts
500VA
170VA
170VA
170VA
4 belts
500VA
170VA
170VA
170VA
Table 1.2 - Power input