MERCURY PLUS
1-137
NOTE 3:
HOW TO CORRECTLY USE THE HEADING PARAMETER IN THE
LABEL PROGRAMMING MODE
Correct use of this parameter, also allows you to print in the initial part of
the label which was hitherto unprintable and proportional to the selected
peeling value (the larger the peeling area expressed in dots, the larger is
the initial unprintable area).
To use this option,you need electronic box with Italora 2.63 my firmware
release (2.74 for table labelling machines) or more recent releases.
Follow the procedure:
1. Program a label with the peeling value most suited to the processing
requirements.
2. Program a data item (e.g. fixed text) in the label with coordinate Y =
0.
3. Measure the space between the beginning of the label at the top and
the beginning of the writing.
Multiply the space, measured in mm, for the printer resolution (8 or
12), thus obtaining the heading length expressed in dots.