September 2021
Installation, Operation and Maintenance Manual
VCIOM-01249-EN Rev. 0
31
Operating the F01-2000
Section 5: Operating the F01-2000
If the upper line of the display shows “
ALARM OFF
”, remove the alarm before going ahead
(see Section 12.10).
If the upper line of the display shows “
WARNING OFF
”, a warning condition is present.
You can go ahead since the F01-2000 is working well, but some datum is not according to
the configured parameters (see Section 12.10).
If the upper line of the display shows “
INT OFF
”, an Interlock input is active. If the upper line
of the display shows “
ESD ON OFF
”, the ESD input is active.
If the following message appears, the base card is F01-2000 v4 type, but the actuator is
equipped with an F01-2000 v0 series terminal board. This may happen if the F01-2000 v4
base card was supplied as a spare card, to replace the base card of the F01-2000 v0
series (see the previous revision of instruction manuals relevant to the F01-2000 and its
optional modules).
Biffi Italia
F01-2000 v4 otb
Do not operate the actuator without first checking that the configuration is according to
the required application by using the “VIEW and SET-UP” features (see Section 6/10).
Set torque limits, position limits and close direction by means of the “stroke limits routine”
of the “actuator set-up” menu (see Section 9).
When the stroke limits and the configurations are correct, bring the 3-position selector to
LOCAL and drive the actuator to open or closed position (see Section 5.4).