Installation
12
Section 3: Installation
Figure 12
Model
Tightening torque (Nm)
F01-2000/150
40
F01-2000/300
40
F01-2000/600
80
Table 4.
Entry
NPT size
Tightening torque (Nm)
1
1"
M32x1.5
2
1 - 1/2"
M40x1.5
3
1"
M32x1.5
4*
3/4"
M25x1.5
Table 5.
3.5
Electrical Connections
Before powering to the actuator check that the supply voltage details on the nameplate
are correct for the plant. Access to terminals for electrical connections and commissioning
is through the terminal cover since all settings are non-intrusive. The removal of any other
covers without Biffi’s approval will invalidate the warranty.
Biffi will not accept any responsibility for any damage or deterioration that may be caused.
NOTICE
All the accessories (in particular cable glands) must be certified according to
94/9/EC Directive.
3.5.1
Identification of Entries
Electric actuators series F01-2000 are equipped with 4 entries (3 are standard the fourth is
supplied when requested).
With reference to Figure 12, the thread form/size for entry is as follows:
NOTE:
* optional