Service and Maintenance for Mortise Locks
4–44
W Series Service Manual
Task C. To turn over the RQE switch:
1. Pull the wire strain relief up and out of the case.
2. Tilt the RQE switch toward the middle of the case, then pull it up
and out of the case.
3. Gently pull the switch bracket feet apart and remove the bracket
from the switch.
4. Reposition the switch lever. For RH/RHRB, the switch lever pivots
at the bottom of the bracket (near the feet). For LH/LHRB, the
switch lever pivots at the top of the bracket.
Figure 4.41
RQE switch assembly anatomy (LH orientation of RQE shown)
RQE switch & wire assembly
Switch bracket feet
Pivot point of the switch lever
Actuator button
Wire strain relief