Installation Instructions for 83KW/93KW–85KW/95KW IDH Max Cylindrical Locks
BEST ACCESS SYSTEMS
Indianapolis, Indiana
Preparing the door and door jamb
8
7
Pull field wire harness through door
1 Feed the field wire harness (connected to the inside
trim) into the field harness & RH/RHRB reader wire
hole and down into the hole drilled through the door
to the hinge mortise.
2 From the latch edge of the door, fish the field wire
harness through the door to the hinge mortise.
3 Make sure there are 3
″
to 4
″
of slack in the field wire
harness to allow access to the control electronics
circuit board in the inside trim.
Note:
You can let the trim dangle from the field wire
harness while completing tasks 8 through 15.
Figure 7
Pulling the field wire harness through the door
Hinge mortise
Field wire
harness
Inside trim
Field harness &
RH/RHRB reader
wire hole
Inside of door