Service and Maintenance for Cylindrical Locks
5–14
W Series Service Manual
Task F. To connect the reader wire harness:
1.
For LH and LHRB doors
From the outside of the door, feed the reader wire harness
connector through the door status switch & LH/LHRB reader wire
hole.
For RH and RHRB doors
From the outside of the door, feed the reader wire harness
connector through the field harness & RH/RHRB reader wire hole.
2. Temporarily rest the outside escutcheon on the door by inserting
the escutcheon studs into the trim holes.
3. Connect the reader wire harness to the control electronics circuit
board in the inside escutcheon.
Caution
When connecting the reader wire harness, make sure that:
■
there are no loose wire connections where the wires are inserted
into the connectors
■
the connectors are firmly mated.
Figure 5.15
Feeding the reader wire harness connector through the wire hole
Reader wire harness
connector
Outside
escutcheon
Outside of door
Field harness &
RH/RHRB reader
wire hole
Door status switch
& LH/LHRB reader
wire hole