Chapter 5 Management of Machine Parameters
To change the machine parameters, you have to input password first. But after you
repower the machine, the machine will be locked again. The details of it are
similar to the “Unlock/Change The Admin Password” .
5.4.5
Unlock the factory password
The procedure is similar to chapter 5.4.2.
5.4.6
Factory Save/Reset Parameters
The procedure is similar to chapter 5.4.3.
5-5
Initialize Parameters
This function can initialize the general embroidery parameters of the machine.
The system saves a group of default parameter values. The factory and
embroidery factory administrator can save their parameter settings. In this
operation it follows the rules at below:
1.
When the factory password and embroidery factory administrator password are not set or
the machine has no password-protected function, all general embroidery parameters are
initialized to their default values.
2.
When that factory password has been set and unlocked, all general embroidery parameters
are initialized to their default values.
3.
When that factory password has been set and locked and administrator password has not
been set or has been canceled, all factory-authorized machine parameters are recovered to
factory saved values and other parameters are initialized to the default values.
4.
When that factory password has been set and locked and administrator password has been
set and locked, all factory-authorized machine parameters are recovered to factory saved values
and administrator authorized machine application parameters are recovered to administrator
saved values and other parameters are initialized to their default values.
5.
When that factory password has not been set and administrator password has been set and
unlocked, all general embroidery parameters are initialized to their default values.
6.
When that factory password has not been set and administrator password has been set and
locked, all administrator-authorized machine application parameters are recovered to
administrator saved values and other parameters are initialized to the default values.
BECS-D56 computerized embroidery machine owner’s manual