AMP8000 and AMP8500
7.4.1.2
AMP8805
ON = status display of the power supply
LED
Status
lit
The device is in operation.
Connection X20 is available for
communication via EtherCAT P.
Flashes
LED flashes for two seconds
when starting the device
off
No or too low mains voltage or
DC link voltage
Us/Up = status display of the power supply
LED
Status
lit
24 V power supply at output X20
off
No 24 V power supply at output
X20
L/A = Link/Activity to display the communication state
LED
Status
lit
LINK: connection to the con-
nected EtherCAT module
Flashes
ACT: communication with con-
nected EtherCAT module
off
No connection to the connected
EtherCAT module