Electrical installation
84
───
Version: 1.1
AMP8000 and AMP8500
9.2
Connection
Beckhoff offers various power connectors. All plugs are IP65 rated.
A protective conductor connection according to VDE 0627 is pro-
vided on the housing.
9.2.1
B23
The following tables show the pin assignment of the input connector
on the motor side:
Contact
Function
1
TX+; GND
s
2
RX+; GND
p
3
RX-; U
p
4
TX-; U
s
5
PE
6
24 V
DC
7
-DC Link
8
+DC Link
9
GND 24 V
DC
9.3
Power supply
For the power supply, the connection X01 is available on the
AMP8620 power supply module.
9.3.1
X01
• X01 connection on the AMP8620 power supply module
Terminal point
Connection
5
PE
6
L1
7
L2
8
L3