Technical description
Version: 1.1
───
63
AMP8000 and AMP8500
7.1
Installation position
7.1.1
Modules
The standard installation position of the modules in the machine or
in the control cabinet is the vertical installation position with the con-
nections facing downwards.
7.1.2
Motors
Observe the maintenance intervals and installation positions
Carry out maintenance at regular intervals.
In the horizontal installation position IM V3, liquid which has been
left on the flange for a longer period can penetrate the motor
through capillary action. In installation position IM V1 liquid can es-
cape.
If you do not observe the maintenance intervals, the motor may
overheat depending on the installation position. Ingress and leak-
age of liquids may damage the motor.
The standard installation position of the motors is the design IM B5
according to DIN 60034-7.
Summary of Contents for AMP8000
Page 1: ...Operating instructions EN AMP8000 and AMP8500 Distributed servo drives 11 15 2022 Version 1 1 ...
Page 2: ......
Page 43: ...Technical data Version 1 1 43 AMP8000 and AMP8500 4 3 1 2AMP8620 2005 0100 4 3 1 2 ...
Page 44: ...Technical data 44 Version 1 1 AMP8000 and AMP8500 4 3 1 3AMP8620 2005 0200 4 3 1 3 ...
Page 47: ...Technical data Version 1 1 47 AMP8000 and AMP8500 4 5 1 2AX8832 0000 0000 4 5 1 2 ...
Page 108: ......