For your safety
Version: 1.1
───
17
AMP8000 and AMP8500
2.2.2
During operation
Observe the discharge times of the capacitors
Observe the following delay times after disconnecting from the
mains supply:
AMP8yxx
30 minutes
AX883x
30 minutes
Do not work on live electrical parts
Only work on the distributed servo drive system when the voltage
has dropped to < 50 V. Measure the voltage and observe the waiting
times. Ensure that the protective conductor is connected properly.
Never loosen electrical connections when live. Disconnect all com-
ponents from the mains and secure them against being switched on
again.
Do not touch hot surfaces
Check the cooling of the surfaces with a thermometer. Do not touch
the components during and immediately after operation. Allow the
components to cool sufficiently after switching off.
Avoid overheating
Operate the components according to the technical specifications.
Refer here to the chapter: "Technical data". Provide for sufficient
cooling. Switch the components off immediately if the temperature is
too high.
Do not touch any moving or rotating components
Do not touch any moving or rotating components. Fasten all parts or
components on the machine or plant.
2.2.3
After operation
De-energize and switch off components before working on
them
Check the functionality of all safety-relevant devices. Secure the
working environment. Secure the machine or plant against being in-
advertently started up. Observe the chapter: "Decommissioning".
Summary of Contents for AMP8000
Page 1: ...Operating instructions EN AMP8000 and AMP8500 Distributed servo drives 11 15 2022 Version 1 1 ...
Page 2: ......
Page 43: ...Technical data Version 1 1 43 AMP8000 and AMP8500 4 3 1 2AMP8620 2005 0100 4 3 1 2 ...
Page 44: ...Technical data 44 Version 1 1 AMP8000 and AMP8500 4 3 1 3AMP8620 2005 0200 4 3 1 3 ...
Page 47: ...Technical data Version 1 1 47 AMP8000 and AMP8500 4 5 1 2AX8832 0000 0000 4 5 1 2 ...
Page 108: ......