Product overview
Version: 1.1
───
35
AMP8000 and AMP8500
3.7.4
Sealing air connection
3.7.4
Ingress of fluids or dust at different temperature ranges can be pre-
vented by a separate sealing air connection with a defined overpres-
sure. The overpressure is achieved by connection to a regulated
compressed air system. It is installed together with an radial shaft-
sealing ring.
A sealing air connection is recommended for:
• Critical installation locations with extreme dust exposure
• Motors with permanent and direct fluid contact
Important
In the horizontal installation position IM V3, liquid can accumulate
permanently on the motor flange and penetrate into the motor. Even
a sealing air connection cannot completely prevent the liquid from
entering.
An air hose provided by the customer must be connected to a suit-
able regulated pressure reducer. The compressed air must be free
of oil and dust.
Minimum requirements and technical data:
Compressed air re-
quirement
according to DIN ISO 8573-1 Class 3:2010
[A:B:C]
Operating pressure
0.1 ± 0.05 bar
Maximum pressure
0.3 bar
Air connection
Quick-release coupling
Required air line
e.g. PA hose 6 mm x 4 mm
Summary of Contents for AMP8000
Page 1: ...Operating instructions EN AMP8000 and AMP8500 Distributed servo drives 11 15 2022 Version 1 1 ...
Page 2: ......
Page 43: ...Technical data Version 1 1 43 AMP8000 and AMP8500 4 3 1 2AMP8620 2005 0100 4 3 1 2 ...
Page 44: ...Technical data 44 Version 1 1 AMP8000 and AMP8500 4 3 1 3AMP8620 2005 0200 4 3 1 3 ...
Page 47: ...Technical data Version 1 1 47 AMP8000 and AMP8500 4 5 1 2AX8832 0000 0000 4 5 1 2 ...
Page 108: ......