Model 58000 Switch Operation
893-878-B
2-33
Figure 2-15. Unsupported configuration: Loop of switch communities
In this configuration, ports 1 and 2 of switches C, D, and G and port 3 of
switches C and E are all configured for feeder mode and are all part of the same
virtual LAN. The feeder links from switch G to switches C and D create a data
loop because these switches can receive data that was originated at one of their
switch ports.
Model 58000
switch A
Model 58000
switch B
Model 58000
switch E
Model 58000
switch F
Model 58000
switch C
Model 58000
switch D
Switch community 1
Switch community 2
Model 58000
switch G
Model 58000
switch H
Switch community 3
Port 3
Port 1
Port 2
Port 1
Port 2
Port 3
= Feeder link
= Trunk link
Port 2
Port 1
6573
key
893-878-B Book Page 33 Monday, May 12, 1997 2:06 PM