BUDE_Manual-CANopen_EN.doc
55/55
Baumer Hübner GmbH
MB703.E – 12A1 – Firmware version 1.0
P.O. Box 12 69 43 · D-10609 Berlin, Germany
23.10.2012 / bja
Phone: +49 (0)30/69003-0 · Fax: +49 (0)30/69003-104
[email protected] · www.baumer.com
Technical modification reserved
6.1.5
Terminal assignment
Terminal
Explanation
CAN_L
CAN bus signal (dominant low)
CAN_H
CAN bus signal (dominant high)
UB
Supply voltage 10 - 30 VDC
GND
Ground terminal for UB
Terminals with the same designation are internally interconnected.
•
Carefully plug the bus cover onto the D-SUB plug of the basic encoder/converter, then press only via the
sealing rubber, taking care not to tilt it. The bus cover must rest fully against the basic encoder/converter.
•
Tighten both the fastening screws firmly in the same direction.
The encoder housing/converter and braided shield of the connecting cable are only ideally connected if the
bus cover is resting fully on the basic encoder/converter (positive locking).
6.2
Display elements (status display)
A dual LED is integrated at the back of the bus cover.
LED green
LED red
Status
Off
Off
Power supply not connected
Flashing
Off
Pre-operational mode
On
Off
Operational mode
On
Off
Stopped/Prepared mode
Off
Flashing
Warning
Off
On
Error