BUDE_Manual-CANopen_EN.doc
41/55
Baumer Hübner GmbH
23.10.2012/bja
Berlin, Germany
Object 6502
Overall measurement range in increments
Subindex
0
Data type
Unsigned 32
Access
Read only
Default
2000h = 8192
13 bit encoder/converter
40000h = 262144
18 bit encoder/converter
20000000h = 536870912
29 bit encoder/converter
EEPROM
No
Description
Maximum measurement range (the data type U32 in this object does
not correspond to the CiA profile)
Values
2000h = 8192
13 bit encoder/converter
40000h = 262144
18 bit encoder/converter
20000000h = 536870912
29 bit encoder/converter
Object 6503
Alarms
Subindex
0
Data type
Unsigned 16
Access
Read only
Default
0h
EEPROM
No
Description
Alarm messages as per object 6504h
Values
Bit 0 = 1
Position error active
Object 6504
Supported alarms
Subindex
0
Data type
Unsigned 16
Access
Read only
Default
1h
EEPROM
No
Description
Alarm messages supported by object 6503h
Values
Bit 0 = Position error
Object 6505
Warnings
Subindex
0
Data type
Unsigned 16
Access
Read only
Default
0h
EEPROM
No
Description
Warnings as per object 6506h
Values
Multiturn:
Bit 2 = 1
CPU watchdog reset
Bit 4 = 1
Battery charge (only AMG 81 C 29)
Singleturn:
Bit 2 = 1
CPU Watchdog reset