BUDE_Manual-CANopen_EN.doc
33/55
Baumer Hübner GmbH
23.10.2012/bja
Berlin, Germany
Objekt 1029
Error Behavior (from Firmware version V1.04)
SubIndex
0
DatenTyp
Unsigned 8
Zugriff
ReadOnly
Default
1
EEPROM
No
Beschreibung
Biggest supported subindex
Werte
1
SubIndex
1
DatenTyp
Unsigned 8
Zugriff
ReadWrite
Default
1
EEPROM
Yes
Beschreibung
Behavior after Communication error
Werte
0h = change to Pre-Operational Mode
1h = no Mode-change
2h = change to Stop Mode
3h = reset node
Object 1800
PDO1 parameters
Subindex
0
Data type
Unsigned 32
Access
Read only
Default
5
EEPROM
No
Description
Biggest supported subindex
Values
5
Subindex
1
Data type
Unsigned 32
Access
Read write
Default
180h + Node ID
EEPROM
Yes
Description
COB ID of the PDO
Values
180h + Node ID
Subindex
2
Data type
Unsigned 8
Access
Read write
Default
FEh
EEPROM
Yes
Description
PDO type
Values
1..n..F0h = PDO has synchronous characteristics (the PDO is
transmitted to each nth SYNC telegram)
FEh =
PDO has asynchronous characteristics (PDOs are
transmitted cyclically depending on the event timer and
event trigger)