89
7.7.14
TimerTriggerActivation
Selects the activation mode of the trigger to start the Timer.
Name
TimerTriggerActivation
Category
CounterAndTimerControl
Interface
IEumeration
Access
Read / Write
Unit
-
Values
RisingEdge
Starts counting on the Rising Edge of the selected trig-
ger signal.
FallingEdge
Starts counting on the Falling Edge of the selected trig-
ger signal.
AnyEdge
Starts counting on the Falling or Rising Edge of the se-
lected trigger signal.
7.7.15 TimerTriggerSource
Selects the source of the trigger to start the Timer.
Name
TimerTriggerSource
Category
CounterAndTimerControl
Interface
IEumeration
Access
Read / Write
Unit
-
Values
Action1
Starts with the assertion of the chosen action signal.
ExposureEnd
Starts with the reception of the Exposure End.
ExposureStart
Starts with the reception of the Exposure Start.
FrameTransfer-
Skipped
Frame Transfer Skipped.
Line0
Starts when the specidfied TimerTriggerActivation
condition is met on the chosen I/O Line.
Line1
Starts when the specified TimerTriggerActivation con
-
dition is met on the chosen I/O Line.
Off
Disables the Timer trigger.
Software
Starts when the trigger was generated by the software.
TriggerSkipped Starts when a trigger was skipped.
Summary of Contents for 11192208