175
7.17.18 OpticControllerStatus
Reads the state of the optic controller.
Name
OpticControllerStatus
Category
OpticControl
Interface
IEnumeration
Access
Read only
Unit
-
Values
Busy
The optic controller executes a feature access/com-
mand.
Error
The optic controller encountered an error.
Not Connected The optic controller is physically not connected.
Not Initialized
The optic controller is not initialized.
Not Supported: The optic controller is physically connected but not
supported.
Ready
The optic controller is ready to use.
7.17.19 OpticControllerTemperature (except .EF)
Optical controller temperature in degrees Celsius (C).
Name
OpticControllerTemperature
Category
OpticControl
Interface
IFloat
Access
Read only
Unit
°C
Values
-127.0 ... 127.0
7.17.20 OpticControllerThermalCompensation (except .EF)
The focus of the lens may change as the operating temperature increases. With this fea-
ture you enable or disable the thermal compensation of the optic controller.
Notice
Function available for Varioptic with firmware ≥ v38.
Name
OpticControllerThermalCompensation
Category
OpticControl
Interface
IBoolean
Access
Read / Write
Unit
-
Values
true = 1 (On)
false = 0 (Off)