115
7.10.15 LineSource
Input
(
Line Selector
→
Line 0 / Line 1
)
The wiring of these input connector is left to the user.
Sole exception is the compliance with predetermined high and low levels (0 .. 4.5 V low,
11 .. 30 V high).
The defined signals will have no direct effect, but can be analyzed and processed on the
software side and used for controlling the camera.
(Input) Line 0
(Input) Line 0
(Input) Line 1
Trigger
state high
state low
state selection
(inverter)
(Input) Line 1
Trigger
state high
state low
Output
(
Line Selector
→
Line 4 / Line 5 / Line 6 / Line 7
)
Selects which internal acquisition or I/O source signal to output on the selected Line.
With this feature, Baumer gives you the option to wire the output connectors to internal
signals that are controlled on the software side.
Signal
s
(Output) Line 4
state high
state low
IO Matrix
state selection
(inverter)
signal selection
(line source)
Signal
s
(Output) Line 5
state high
state low
Signal
s
(Output) Line 6
state high
state low
Signals
(Output) Line 7
state high
state low
(Output) Line 4
(Output) Line 5
(Output) Line 6
(Output) Line 7
Name
LineSource
Category
DigitalIOControl
Interface
IEnumeration
Access
Read / Write
Unit
-
Values
see table below