107
7.10.1 LineDebouncerHighTimeAbs
Sets the absolute value of the selected line debouncer time in microseconds for switch
from low to high.
Name
LineDebouncerHighTimeAbs
Category
DigitalIOControl
Interface
IFloat
Access
Read / Write
Unit
µs
Values
0.000000 - 5,000.000000 (Increment: 1.00)
7.10.2 LineDebouncerLowTimeAbs
Sets the absolute value of the selected line debouncer time in microseconds for switch
from high to low.
Name
LineDebouncerLowTimeAbs
Category
DigitalIOControl
Interface
IFloat
Access
Read / Write
Unit
µs
Values
0.000000 - 5,000.000000 (Increment: 1.00)