111
Electrical specifications (Output Line4 ... Line7)
Danger!
Use in wet environments requiring IP67 protection
Risk of electric shock. Electric shock can be fatal or cause serious injury.
Use is only permitted under consideration of pollution degree 2 and overvoltage
category 2.
The M12 connectors must comply with the IEC 61076-2-101 standard.
The dielectric strength and withstand voltage for the plug/socket combination must
be checked according to DIN EN 60664-1:2008-01 for 60 V.
U
EXT
: UL conform applications: 12 V (- 20 %) … 24 V (+ 20 %)
U
EXT
: not UL conform applications: 12 V (- 20 %) … 48 V (+ 10 %)
I
OUT
:
- max. 1.5 A permanently in sum or per output individually
- Pulse 40 % of the period, max. 2.5 A (t
ON
max 1 s)
- t
ON
= < 0.2 μs / t
OFF
= < 0.2 μs
- max. Frequency: 500 kHz
Notice
In case of overload or short circuit, the outputs are disabled. To re-enable the output,
disconnect Power (IO) (pin 12) from the power supply or perform a
DeviceReset
.
7.10.7 LinePWMDuration
Sets the pulse time in μs, with which the illumination is pulsed.
Name
LinePWMDuration
Category
DigitalIOControl
Interface
IInteger
Access
Read / Write
Unit
µs
Values
1 - 5000 (Increment: 1)
7.10.8 LinePWMDutyCycle
Sets the duty cycle (ratio of pulse duration to period time duration) in %. This value is
specified by the connected illumination.
Name
LinePWMDutyCycle
Category
DigitalIOControl
Interface
IInteger
Access
Read / Write
Unit
%
Values
1 - 100 (Increment: 1)