170
7.17.3 ApertureStatus (.EF only)
Reads the status of the Aperture feature.
Name
ApertureStatus
Category
OpticControl
Interface
IEnumeration
Access
Read only
Unit
-
Values
Busy
The aperture executes a feature access/command.
Error
The aperture encountered an error.
Not Connected
The aperture is physically not connected.
Not Initialized
The aperture is not initialized.
Not Supported
The aperture is physically connected but not support-
ed.
Ready
The aperture is ready to use.
7.17.4 ApertureStepper (.EF only)
ApertureStepper controls the stepper value of the Aperture. The minimum value is the
maximum aperture.
Name
ApertureStepper
Category
OpticControl
Interface
IInteger
Access
Read / Write
Unit
-
Values
e.g. 42 ... 85 (Increment: 1)
value range depending on lens
7.17.5 FocalLength
Focal length in millimeters.
Name
FocalLength
Category
OpticControl
Interface
IFloat
Access
Read only
Unit
mm
Values
e.g. 0 ... 4,294,967,295,000000 (Increment:1.00)
value range depending on lens