25
4. Installation
Caution
!
The installer of the system is responsible for the safety of the system in
which the camera is integrated.
4.1
Environmental Requirements
Storage
temperature
-10 °C (+14 °F) ... +70 °C (+158 °F)
Humidity
10 % ... 90 % non condensing
4.2 Ambient Temperature / Heat Transmission
Caution
Heat can damage the camera.
Ambient temperature above 25 °C (77 °F)
requires heat dissipation measures.
Provide adequate dissipation of heat,
to ensure that the temperatures does not exceed
the specified values.
Baumer recommends the following methods for proper heat dissipation:
▪
Every form of convection around the device and mounting helps reduce
temperature. Prevent heat from becoming trapped!
▪
Mounting in combination with forced convection may provide proper heat
dissipation.
▪
Avoid mounting onto stainless steel. Stainless steel has a roughly 10-fold
lower thermal conductivity compared to aluminium.
▪ Do not install the device at the end of a profile; this will allow heat to
dissipate on both sides (higher temperature drops over a larger area)!
▪
Do not operate other devices in close proximity to the camera. Their
waste heat could additionally heat the camera.
▪
From an ambient temperature of +30 °C (86 °F) up to +40 °C (104 °F) the
camera requires forced air cooling (min. 0.9 m/s).